Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
12.
Clin Epigenetics ; 14(1): 116, 2022 09 19.
Article in English | MEDLINE | ID: mdl-36123616

ABSTRACT

Lung cancer patients are diagnosed at late stages when curative treatments are no longer possible; thus, molecular biomarkers for noninvasive detection are urgently needed. In this sense, we previously identified and validated an epigenetic 4-gene signature that yielded a high diagnostic performance in tissue and invasive pulmonary fluids. We analyzed DNA methylation levels using the ultrasensitive digital droplet PCR in noninvasive samples in a cohort of 83 patients. We demonstrated that BCAT1 is the candidate that achieves high diagnostic efficacy in circulating DNA derived from plasma (area under the curve: 0.85). Impact of potentially confounding variables was also explored.


Subject(s)
Cell-Free Nucleic Acids , Lung Neoplasms , Biomarkers, Tumor/genetics , Cell-Free Nucleic Acids/genetics , DNA , DNA Methylation , Epigenesis, Genetic , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/genetics , Transaminases/genetics
13.
ERJ Open Res ; 7(3)2021 Jul.
Article in English | MEDLINE | ID: mdl-34258257

ABSTRACT

BACKGROUND: The role of bronchoscopy in coronavirus disease 2019 (COVID-19) is a matter of debate. PATIENTS AND METHODS: This observational multicentre study aimed to analyse the prognostic impact of bronchoscopic findings in a consecutive cohort of patients with suspected or confirmed COVID-19. Patients were enrolled at 17 hospitals from February to June 2020. Predictors of in-hospital mortality were assessed by multivariate logistic regression. RESULTS: A total of 1027 bronchoscopies were performed in 515 patients (age 61.5±11.2 years; 73% men), stratified into a clinical suspicion cohort (n=30) and a COVID-19 confirmed cohort (n=485). In the clinical suspicion cohort, the diagnostic yield was 36.7%. In the COVID-19 confirmed cohort, bronchoscopies were predominantly performed in the intensive care unit (n=961; 96.4%) and major indications were: difficult mechanical ventilation (43.7%), mucus plugs (39%) and persistence of radiological infiltrates (23.4%). 147 bronchoscopies were performed to rule out superinfection, and diagnostic yield was 42.9%. There were abnormalities in 91.6% of bronchoscopies, the most frequent being mucus secretions (82.4%), haematic secretions (17.7%), mucus plugs (17.6%), and diffuse mucosal hyperaemia (11.4%). The independent predictors of in-hospital mortality were: older age (OR 1.06; p<0.001), mucus plugs as indication for bronchoscopy (OR 1.60; p=0.041), absence of mucosal hyperaemia (OR 0.49; p=0.041) and the presence of haematic secretions (OR 1.79; p=0.032). CONCLUSION: Bronchoscopy may be indicated in carefully selected patients with COVID-19 to rule out superinfection and solve complications related to mechanical ventilation. The presence of haematic secretions in the distal bronchial tract may be considered a poor prognostic feature in COVID-19.

14.
J Infect ; 82(2): 261-269, 2021 02.
Article in English | MEDLINE | ID: mdl-33440207

ABSTRACT

OBJECTIVE: To determine the incidence, characteristics, and risk factors of pulmonary embolism (PE) among patients hospitalized for COVID-19. PATIENTS AND METHODS: We performed a prospective observational study of a randomly selected cohort of consecutive patients hospitalized for COVID-19 infection between March 8, 2020 through April 25, 2020. All eligible patients underwent a computed tomography pulmonary angiography independently of their PE clinical suspicion and were pre-screened for a baseline elevated D-dimer level. RESULTS: 119 patients were randomly selected from the 372 admitted to one tertiary hospital in Valencia (Spain) for COVID-19 infection during the period of study. Seventy-three patients fulfilled both the inclusion criteria and none of the exclusion criteria and were finally included in the study. Despite a high level of pharmacological thromboprophylaxis (89%), the incidence of PE was 35.6% (95% confidence interval [CI], 29.6 to 41.6%), mostly with a peripheral location and low thrombotic load (Qanadli score 18.5%). Multivariate analysis showed that heart rate (Hazard Ratio [HR], 1.04), room-air oxygen saturation (spO2) (HR, 0.87), D-dimer (HR, 1.02), and C-reactive protein (CRP) levels (HR, 1.01) at the time of admission were independent predictors of incident PE during hospitalization. A risk score was constructed with these four variables showing a high predictive value of incident PE (AUC-ROC: 0.86; 95% CI: 0.80 to 0.93). CONCLUSIONS: Our findings confirmed a high incidence of PE in hospitalized COVID-19 patients. Heart rate, spO2, D-dimer, and CRP levels at admission were associated with higher rates of PE during hospitalization.


Subject(s)
COVID-19/complications , Pulmonary Embolism , Venous Thromboembolism , Aged , Anticoagulants/therapeutic use , Female , Fibrin Fibrinogen Degradation Products/analysis , Hospitalization , Humans , Incidence , Male , Middle Aged , Prospective Studies , Pulmonary Embolism/epidemiology , Risk Factors , Spain/epidemiology , Venous Thromboembolism/epidemiology
17.
Arch. bronconeumol. (Ed. impr.) ; 52(5): 244-249, mayo 2016. ilus, tab
Article in Spanish | IBECS | ID: ibc-151807

ABSTRACT

Introducción y objetivos: La ecografía como guía en la punción percutánea de lesiones torácicas periféricas (LTP) ofrece ventajas frente a otras técnicas de imagen. La mayoría de los estudios con esta técnica han sido comunicados por radiólogos intervencionistas. El objetivo de este estudio ha sido analizar la rentabilidad diagnóstica de la punción percutánea guiada por ecografía en una unidad de técnicas de neumología. Metodología: Estudio retrospectivo de 58 pacientes con LTP puncionadas con visualización ecográfica en tiempo real, entre el 1 de marzo de 2011 y el 1 de septiembre de 2014. Los resultados fueron divididos en 3 categorías diagnósticas: maligna, benigna y no diagnóstica (ND); esta última incluye los resultados de benignidad no específica (SD) y los de muestra insuficiente para diagnóstico (MID). Resultados: Se obtuvo: resultado maligno en 34 (58,6%) de los procedimientos, resultado benigno en 13 (22,4%) y ND en 11 (19%) (SD en 5 [8,6%] y MID en 6 [10,3%]). En 5 de los casos ND el resultado final fue de malignidad y en 4 de ellos se tratada de una MID. La sensibilidad diagnóstica obtenida fue del 75,6%, el valor predictivo negativo del 54,2%, y la especificidad y el valor predictivo positivo del 100%, con una rentabilidad diagnóstica del 81%. Cuando se excluyeron los casos con MID los valores fueron del 87,2%, 72,3%, 100% y 100%, respectivamente, con una rentabilidad diagnóstica del 90,4%. No hubo complicaciones graves con la técnica. Conclusiones: La punción percutánea bajo guía ecográfica en LTP realizada por neumólogos intervencionistas es una técnica segura y con una alta rentabilidad diagnóstica


Introduction and objectives: The use of ultrasound in peripheral thoracic lesions offers advantages over other radiological guiding methods. This diagnostic procedure has been applied in most studies published by radiologists. Our aim was to determine the diagnostic efficacy of percutaneous ultrasound-guided punctures and biopsies of peripheral thoracic lesions performed by pulmonologists. Methodology: A retrospective analysis of 58 patients who underwent real-time ultrasound-guided transthoracic punctures and biopsy of peripheral thoracic lesions between March 2011 and September 2014 in the pulmonology department of our hospital. Cases were classified into the following diagnostic categories: malignant, benign and non-diagnostic (non-specific benign without evidence of malignancy and insufficient specimen). Results: A conclusive diagnosis was obtained in 47 procedures (81%), of which 13 (22.4%) were specific benign lesions and 34 (58.6%) cancers. In the remaining 11 (19%) patients, a non-diagnostic result was obtained [non-specific benign in 5 cases (8.6%) and insufficient specimen in 6 (10.3%)]. Sensitivity was 75.6%, negative predictive value was 54.2%, specificity and positive predictive value were 100%, and diagnostic accuracy was 81%. Excluding procedures with insufficient specimens, the results were 87.2%, 72.3%, 100%, 100% and 90.4% respectively. There were no serious complications. Conclusions: Percutaneous ultrasound-guided puncture and biopsy in the diagnosis of peripheral thoracic lesions performed by pulmonologists is a safe procedure with high diagnostic accuracy. We achieved similar results to those previously obtained by radiologists


Subject(s)
Humans , Male , Female , Thoracic Injuries/pathology , Thoracic Injuries , Ultrasonography/instrumentation , Ultrasonography/methods , Ultrasonography/trends , Biopsy, Needle/instrumentation , Biopsy, Needle/methods , Biopsy, Needle , Image-Guided Biopsy/instrumentation , Image-Guided Biopsy/methods , Image-Guided Biopsy , Cost-Benefit Analysis/methods , Cost-Benefit Analysis , Ultrasonography, Doppler, Color/instrumentation , Ultrasonography, Doppler, Color/methods , Ultrasonography, Doppler, Color/trends , Retrospective Studies , Lung Neoplasms/prevention & control , Lung Neoplasms , Pulmonary Medicine , Japan
18.
Arch. bronconeumol. (Ed. impr.) ; 52(1): 5-11, ene. 2016. ilus, tab
Article in Spanish | IBECS | ID: ibc-147913

ABSTRACT

Introducción: La sedación durante la ecobroncoscopia es importante debido a la duración prolongada de esta exploración. Evaluamos distintos modelos de sedación y sus complicaciones. Método: Se realizó un estudio multicéntrico, prospectivo y observacional en el que recogieron distintas variables en 307 pacientes con distintos modelos de sedación: a) midazolam en bolo; b)propofol en perfusión; c) midazolam en bolo y propofol en perfusión; d) propofol en perfusión y remifentanilo en perfusión, y e) midazolam en bolo y fentanilo en bolo. Finalizada la prueba, los pacientes contestaron una encuesta de satisfacción. Resultados: Los pacientes por modelo de sedación fueron: A 24, B 37, C 107, D 62 y E 77. Las puntuaciones de las sensaciones percibidas de recuerdo, dolor, tos, disnea y exploración prolongada (0,65 ± 1,11; 0,3 ± 0,73; 0,46 ± 0,9; 0,29 ± 0,73; 0,59 ± 0,96) fueron menores frente a miedo y nerviosismo antes de la exploración (1,26 ± 1,37 y 1,5 ± 1,41). Los valores elevados de indiferencia ante la repetición (1,49 ± 1,3) y de sensación agradable de la prueba (1,23 ± 1,17), junto con cifras bajas la sensación de angustia (0,49 ± 0,85) e incomodidad de la exploración (0,62 ± 1,1), muestran que los distintos modelos de sedación fueron bien tolerados. El 46,6% de los pacientes no encontraron ningún momento malo y el 89,6% se repetiría la prueba. Los modelos E y C fueron los que menos complicaciones presentaron (12,9 y 31,7%) y, en todos los casos, se resolvieron con medidas terapéuticas sencillas. Conclusiones: Los modelos de sedación analizados fueron bien tolerados y la mayoría aceptarían la repetición de la ecobroncoscopia. Las complicaciones fueron escasas y sencillas de resolver


Introduction: Sedation during endobronchial ultrasound (EBUS) is essential due to the long duration of this procedure. We evaluated different models of sedation and their complications. Method: A multicenter, prospective, observational study of 307 patients undergoing EBUS was conducted. Patients were sedated with: a) midazolam bolus; b) propofol infusion; c) midazolam bolus and propofol infusion; d) propofol infusion and remifentanil infusión, or e)midazolam bolus and fentanyl bolus, and clinical variables were collected. Patients were asked to complete a satisfaction survey following the test. Results: Patients per sedation model were: A 24, B 37, C 107, D 62 and E 77. Scores for perceived sensations of recall, pain, cough, dyspnea and prolonged examination (0.65 ± 1.11; 0 3 ± 0.73, 0.46 ± 0.9, 0.29 ± 0.73, and 0.59 ± 0.96, respectively) were lower compared to fear and nervousness before the examination (1.26 ± 1.37 and 1.5 ± 1.41, respectively). High levels of indifference to repeating the procedure (1.49±1.3) and a reported pleasant feeling during the test (1.23±1.17), with low levels of anxiety (0.49 ± 0.85) and discomfort (0.62 ± 1.1), show that different models of sedation were well tolerated. Almost half the patients (46.6%) did not report any "worst momento" during the procedure, and 89.6% were willing to undergo a repeat test. The E and C models presented fewest complications (12.9 and 31.7%, respectively), and all were resolved with simple therapeutic measures. Conclusions: The models of sedation evaluated were well tolerated and most patients were willing to undergo repeat EBUS. Complications were few and easily resolved


Subject(s)
Humans , Male , Female , Deep Sedation/instrumentation , Deep Sedation/methods , Deep Sedation , Bronchoscopy/methods , Bronchoscopy , Deep Sedation/classification , Deep Sedation/standards , Deep Sedation/trends , Safety/standards , Midazolam/therapeutic use , Propofol/therapeutic use , Fentanyl/therapeutic use , Prospective Studies
19.
Arch Bronconeumol ; 52(1): 5-11, 2016 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-26071369

ABSTRACT

INTRODUCTION: Sedation during endobronchial ultrasound (EBUS) is essential due to the long duration of this procedure. We evaluated different models of sedation and their complications. METHOD: A multicenter, prospective, observational study of 307 patients undergoing EBUS was conducted. Patients were sedated with: a) midazolam bolus; b) propofol infusion; c) midazolam bolus and propofol infusion; d) propofol infusion and remifentanil infusión, or e) midazolam bolus and fentanyl bolus, and clinical variables were collected. Patients were asked to complete a satisfaction survey following the test. RESULTS: Patients per sedation model were: A 24, B 37, C 107, D 62 and E 77. Scores for perceived sensations of recall, pain, cough, dyspnea and prolonged examination (0.65±1.11; 0 3±0.73, 0.46±0.9, 0.29±0.73, and 0.59±0.96, respectively) were lower compared to fear and nervousness before the examination (1.26±1.37 and 1.5±1.41, respectively). High levels of indifference to repeating the procedure (1.49±1.3) and a reported pleasant feeling during the test (1.23±1.17), with low levels of anxiety (0.49±0.85) and discomfort (0.62±1.1), show that different models of sedation were well tolerated. Almost half the patients (46.6%) did not report any "worst moment" during the procedure, and 89.6% were willing to undergo a repeat test. The E and C models presented fewest complications (12.9 and 31.7%, respectively), and all were resolved with simple therapeutic measures. CONCLUSIONS: The models of sedation evaluated were well tolerated and most patients were willing to undergo repeat EBUS. Complications were few and easily resolved.


Subject(s)
Bronchoscopy , Conscious Sedation , Deep Sedation , Endosonography , Adult , Aged , Aged, 80 and over , Bronchoscopy/adverse effects , Conscious Sedation/adverse effects , Deep Sedation/adverse effects , Female , Humans , Hypnotics and Sedatives/therapeutic use , Male , Middle Aged , Models, Theoretical , Patient Satisfaction , Prospective Studies
20.
Arch Bronconeumol ; 52(5): 244-9, 2016 May.
Article in English, Spanish | MEDLINE | ID: mdl-26411258

ABSTRACT

INTRODUCTION AND OBJECTIVES: The use of ultrasound in peripheral thoracic lesions offers advantages over other radiological guiding methods. This diagnostic procedure has been applied in most studies published by radiologists. Our aim was to determine the diagnostic efficacy of percutaneous ultrasound-guided punctures and biopsies of peripheral thoracic lesions performed by pulmonologists. METHODOLOGY: A retrospective analysis of 58 patients who underwent real-time ultrasound-guided transthoracic punctures and biopsy of peripheral thoracic lesions between March 2011 and September 2014 in the pulmonology department of our hospital. Cases were classified into the following diagnostic categories: malignant, benign and non-diagnostic (non-specific benign without evidence of malignancy and insufficient specimen). RESULTS: A conclusive diagnosis was obtained in 47 procedures (81%), of which 13 (22.4%) were specific benign lesions and 34 (58.6%) cancers. In the remaining 11 (19%) patients, a non-diagnostic result was obtained [non-specific benign in 5 cases (8.6%) and insufficient specimen in 6 (10.3%)]. Sensitivity was 75.6%, negative predictive value was 54.2%, specificity and positive predictive value were 100%, and diagnostic accuracy was 81%. Excluding procedures with insufficient specimens, the results were 87.2%, 72.3%, 100%, 100% and 90.4% respectively. There were no serious complications. CONCLUSIONS: Percutaneous ultrasound-guided puncture and biopsy in the diagnosis of peripheral thoracic lesions performed by pulmonologists is a safe procedure with high diagnostic accuracy. We achieved similar results to those previously obtained by radiologists.


Subject(s)
Biopsy/methods , Lung Diseases/diagnostic imaging , Ultrasonography, Interventional , Aged , Biopsy/instrumentation , Biopsy, Needle , Computer Systems , Diagnosis, Differential , Female , Hospital Units , Humans , Lung Neoplasms/diagnostic imaging , Male , Middle Aged , Predictive Value of Tests , Pulmonary Medicine , Radiology , Retrospective Studies , Sensitivity and Specificity , Transducers, Pressure , Ultrasonography, Interventional/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...